So Your Redundant Network Might Not Be Redundant

From the classic backhoe cutting through a cable to redundant network paths, data protection, user connectivity, and the cost of building infrastructure that can survive failures, we explore where redundancy helps and where it can create a false sense of security. We also discuss alternative approaches, practical prevention, and why the real test of redundancy isn’t how good the diagram looks, but what happens when something disappears.

Listen now on Apple Music, Spotify, Deezer, Youtube or where-ever you get your panic attacks.

Backhoe Disasters: The Unexpected Menace

The backhoe has been a natural enemy of IT infrastructure for decades. In my early days on the job, one of the warning signs was a small orange tent appearing somewhere down the street. The telco was doing some routine work. Ten minutes later, the phones were down, the network was gone, and suddenly everybody wanted to know what happened.

In the late ’90s, a damaged cable could leave a site without connectivity for days. Andrew remembers several incidents where construction work involving pneumatic hammers, power saws, or heavier equipment managed to cut through critical phone and network cabling.

The Backhoe’s Natural Habitat

“Fibers don’t fight back. They’re everywhere—from every road work to utility trench.”

It became a familiar lesson: when construction work appears near your connectivity, pay attention. A redundant network isn’t particularly redundant if both of your supposedly independent connections eventually disappear into the same hole in the ground.

Network Failover

Network failover is about keeping services available when part of the infrastructure disappears. A second network connection may help with a local failure, but keeping an application available through a larger outage requires considerably more planning.

Ideally, critical applications can operate across multiple sites, with the infrastructure designed to move traffic when one location becomes unavailable. That can include DNS-level solutions such as F5 Global Traffic Manager, alongside redundancy in the application and data layers.

The problem is cost. Building and maintaining completely independent infrastructure across multiple locations can become expensive very quickly. Cloud services have made some of these approaches more accessible to smaller organizations, but the level of redundancy still has to make sense for the business and the consequences of downtime.

Data Redundancy: Reducing Points of Failure

Redundancy doesn’t stop at the network connection. If services need to survive the loss of an entire site, the data and applications behind them also need somewhere else to go.

Larger environments can spread infrastructure across multiple data centers, with independent connections between them. Smaller organizations may keep everything in a single building, accepting that the building itself then remains a single point of failure.

Application design matters as well. Systems need to be designed so that services and data can continue operating from another location when part of the infrastructure fails. Simply having another server somewhere isn’t enough if the application cannot actually use it.

And even perfectly redundant data centers don’t solve everything. The users still need to be able to reach them. That brings us to the other side of the connection: client-side redundancy.

User Connectivity: The Key to Redundancy

Redundant infrastructure is of little use if users can’t reach it. A business may have multiple data centers and carefully designed failover, while still depending on a single connection from the office to the outside world.

4G or 5G can provide a useful backup, but it introduces another dependency. When a fiber cut affects an entire area, potentially thousands of users may switch to mobile connectivity at the same time. The nearby cellular network can become overloaded just when everyone expects it to provide their backup connection.

For critical sites, redundancy therefore needs to consider genuinely different paths and technologies. Depending on the location, that could include cellular, satellite, or point-to-point wireless links rather than relying entirely on another cable in the ground.

Cost of Redundancy: Evaluating ROI

Redundancy comes at a cost, so the question eventually becomes how much downtime the business is willing to accept. One way to approach that is to compare the cost of an outage, including lost revenue and employee productivity, with the cost of the infrastructure needed to prevent or reduce it.

“Is it worth having hours of downtime and risking revenue, or would a second firewall be more cost-efficient?”

There is no single answer. The calculation depends on the organization, the importance of the service, and how expensive an outage becomes before the additional redundancy pays for itself.

Alternative Solutions: Exploring Your Options

Redundancy doesn’t necessarily mean buying a second identical connection. The important part is making sure the backup doesn’t depend on the same infrastructure as the primary connection. That could mean physically separate cable routes, another provider, satellite connectivity, or even a residential connection if it gives you a genuinely independent path.

Where possible, keeping the same IP ranges across different Internet providers can make failover easier, although the available options vary by provider and location. The goal is to find the right balance between independence, available bandwidth, and cost rather than simply duplicating the existing connection.

Avoiding Backhoe Traps

Sometimes the simplest prevention is also the most obvious: know what’s underground before anyone starts digging. Cable routes should be properly documented, marked, and communicated to contractors before construction work begins.

“Call before you dig. If they assure you there’s nothing to worry about, it may be time to double-check!”

And don’t assume that because someone checked, the information is necessarily complete. Knowing where your infrastructure runs, communicating with contractors, and verifying before the first shovel or backhoe hits the ground can prevent a very expensive outage.